J/A+A/329/482   ROSAT Deep Survey in the Lockman Hole          (Hasinger+, 1998)

The ROSAT Deep Survey. I. X-ray sources in the Lockman Field. Hasinger G., Burg R., Giacconi R., Schmidt M., Truemper J., Zamorani G. <Astron. Astrophys., 329, 482-494 (1998)> =1998A&A...329..482H 1998A&A...329..482H
ADC_Keywords: X-ray sources ; Galaxy catalogs Mission_Name: ROSAT Keywords: surveys - cosmology: diffuse radiations - X-rays: galaxies Abstract: The ROSAT Deep Survey in the Lockman Hole is the most sensitive X-ray survey performed to date, encompassing an exposure time of 207ksec with the PSPC and a total of 1.32Msec with the HRI aboard ROSAT. Here we present the complete catalogue of 50 X-ray sources with PSPC fluxes (0.5-2 keV) above 5.5x10-15erg/cm2/s. File Summary: -------------------------------------------------------------------------------- FileName Lrecl Records Explanations -------------------------------------------------------------------------------- ReadMe 80 . This file table4.dat 89 50 Source Catalogue -------------------------------------------------------------------------------- See also: J/A+A/371/833 : ROSAT Ultra Deep Survey (Lehmann+, 2001) J/PASJ/53/445 : ASCA Deep survey in Lockman Hole Field (Ishisaki+, 2001) Byte-by-byte Description of file: table4.dat -------------------------------------------------------------------------------- Bytes Format Units Label Explanations -------------------------------------------------------------------------------- 1- 2 A2 --- --- [RX] 4- 19 A16 --- RX RX source name (based on J2000 position) 21- 23 I3 --- Nb Internal source number 25- 26 I2 h RAh Right ascension (J2000) 28- 29 I2 min RAm Right ascension (J2000) 31- 34 F4.1 s RAs Right ascension (J2000) 36 A1 --- DE- Declination sign (J2000) 37- 38 I2 deg DEd Declination (J2000) 40- 41 I2 arcmin DEm Declination (J2000) 43- 46 F4.1 arcsec DEs Declination (J2000) 48- 50 F3.1 arcsec errPos Position error 51 A1 --- n_errPos [HPR] Note on position error (1) 54- 58 F5.2 10-17W/m2 FX PSPC X-ray flux at 0.5-2keV 60- 63 F4.2 10-17W/m2 e_FX rms uncertainty on FX 66- 70 F5.2 --- HR1 Soft hardness ratio, HR1 = (H-S)/(H+S) (2) 72- 75 F4.2 --- e_HR1 rms uncertainty on HR1 78- 82 F5.2 --- HR2 Hard hardness ratio, HR2 = (H2-H1)/(H2+H1) (2) 84- 87 F4.2 --- e_HR2 rms uncertainty on HR2 -------------------------------------------------------------------------------- Note (1): Dominant weight to the X-ray position comes from PSPC (P) pointing, HRI (H) pointing or HRI (R) raster scan. Note (2): Bands: H: hard band, 0.5-2.0KeV S: soft band, 0.1-0.4keV H1: split hard band, 0.5-0.9keV H2: split hard band, 0.9-2.0keV -------------------------------------------------------------------------------- Acknowledgements: Heinz Andernach (catalog A394 in his collection) References: Schmidt et al., Paper II 1998A&A...329..495S 1998A&A...329..495S Lehmann et al., Paper III 2000A&A...354...35L 2000A&A...354...35L Hasinger et al., Paper IV 1998A&A...340L..27H 1998A&A...340L..27H Zomorani et al., Paper V 1999A&A...346..731Z 1999A&A...346..731Z Lehmann et al., Paper VI 2001A&A...371..833L 2001A&A...371..833L, Cat. J/A+A/371/833 Thompson et al., Paper VII 2001A&A...377..778T 2001A&A...377..778T
(End) Patricia Bauer [CDS] 30-Nov-2003
The document above follows the rules of the Standard Description for Astronomical Catalogues; from this documentation it is possible to generate f77 program to load files into arrays or line by line