J/A+AS/106/29     Flat-spectrum radio sources at 327 MHz           (Ghosh+ 1994)

Three-year monitoring of a sample of flat-spectrum radio sources at 327 MHz. Ghosh T., Gopal-Krishna, Rao A.P. <Astron. Astrophys. Suppl. Ser. 106, 29 (1994)> =1994A&AS..106...29G 1994A&AS..106...29G
ADC_Keywords: Radio sources; Active gal. nuclei; Keywords: active galactic nuclei - radio sources - low frequency variability File Summary: -------------------------------------------------------------------------------- FileName Lrecl Records Explanations -------------------------------------------------------------------------------- ReadMe 80 . This file table1 262 46 Flux-density measurements for the compact-source sample table2 263 36 Flux-density measurements for the control and calibrator sample -------------------------------------------------------------------------------- Byte-by-byte Description of file: table1 table2 -------------------------------------------------------------------------------- Bytes Format Units Label Explanations -------------------------------------------------------------------------------- 1- 8 A8 --- 3C Standard convention denomination (IAU/3C etc.) 10- 13 A4 --- Class Source classification (see text.) 15- 23 A9 --- Name Other name 28 A1 --- l_GAMMA limit flag for GAMMA 29- 32 F4.1 --- GAMMA Corrected variability index (see text) 35- 38 F4.1 --- Stat. Statistical significance of the variation (see text) 41- 42 A2 --- com. comment (only in table1) 44- 51 A8 "DD/MM/YY" Obs1 Epoch of the flux density measurement 53- 59 F7.1 mJy F327MHz1 Flux density at 327-MHz 61- 66 F6.1 mJy e_F327MHz1 rms uncertainty on F327MHz1 69- 76 A8 "DD/MM/YY" Obs2 Epoch of the flux density measurement 78- 84 F7.1 mJy F327MHz2 Flux density at 327-MHz2 86- 91 F6.1 mJy e_F327MHz2 rms uncertainty on F327MHz2 93-100 A8 "DD/MM/YY" Obs3 Epoch of the flux density measurement 102-108 F7.1 mJy F327MHz3 []? Flux density at 327-MHz3 110-115 F6.1 mJy e_F327MHz3 []? rms uncertainty on F327MHz3 118-125 A8 "DD/MM/YY" Obs4 Epoch of the flux density measurement 127-133 F7.1 mJy F327MHz4 []? Flux density at 327-MHz4 135-140 F6.1 mJy e_F327MHz4 []? rms uncertainty on F327MHz4 142-149 A8 "DD/MM/YY" Obs5 Epoch of the flux density measurement 151-157 F7.1 mJy F327MHz5 []? Flux density at 327-MHz5 159-164 F6.1 mJy e_F327MHz5 []? rms uncertainty on F327MHz5 167-174 A8 "DD/MM/YY" Obs6 Epoch of the flux density measurement 176-182 F7.1 mJy F327MHz6 []? Flux density at 327-MHz6 184-189 F6.1 mJy e_F327MHz6 []? rms uncertainty on F327MHz6 191-198 A8 "DD/MM/YY" Obs7 Epoch of the flux density measurement 200-206 F7.1 mJy F327MHz7 []? Flux density at 327-MHza7 208-213 F6.1 mJy e_F327MHz7 []? rms uncertainty on F327MHz7 216-223 A8 "DD/MM/YY" Obs8 Epoch of the flux density measurement 225-231 F7.1 mJy F327MHz8 []? Flux density at 327-MHza8 233-238 F6.1 mJy e_F327MHz8 []? rms uncertainty on F327MHz8 240-247 A8 "DD/MM/YY" Obs9 Epoch of the flux density measurement 249-255 F7.1 mJy F327MHz9 []? Flux density at 327-MHz9 257-262 F6.1 mJy e_F327MHz9 []? rms uncertainty on F327MHz9 --------------------------------------------------------------------------------
(End) Patricia Bauer [CDS] 09-May-1994
The document above follows the rules of the Standard Description for Astronomical Catalogues; from this documentation it is possible to generate f77 program to load files into arrays or line by line