J/PAZh/26/355 Catalog of X-ray sources from TTM/COMIS (Emelyanov+, 2000)
A Catalog of X-ray sources as observed by the TTM/COMIS telescope onboard
the Mir-Kvant observatory in 1988-1998.
Emelyanov A.N., Aleksandrovich N.L., Sunyaev R.A.
<Pis'ma Astron. Zh. 26, 355 (2000)>
=2000PAZh...26..355E 2000PAZh...26..355E
=2000AstL...26..297E 2000AstL...26..297E
ADC_Keywords: X-ray sources
Abstract:
A Catalog of X-ray sources as observed by the TTM/COMIS telescope
onboard the Mir-Kvant observatory is presented. Brief information
about the 67 sources detected at a confidence level higher than
4σ between 1988 and 1998 is provided. X-ray properties and
charateristic spectra of different types of sources are briefly
described.
File Summary:
--------------------------------------------------------------------------
FileName Lrecl Records Explanations
--------------------------------------------------------------------------
ReadMe 80 . This file
table1.dat 164 67 Catalog of X-ray sources
--------------------------------------------------------------------------
See also:
VII/80 : The HEAO A-1 X-Ray Source Catalog (Wood+, 1984)
VII/81 : The Second catalogue of X-ray sources (Amnuel+, 1982)
IX/13 : The 2E Catalogue (Harris+ 1994)
IX/31 : The WGACAT version of ROSAT sources (White+ 2000)
Byte-by-byte Description of files: table1.dat
--------------------------------------------------------------------------
Bytes Format Units Label Explanations
--------------------------------------------------------------------------
1- 13 A13 --- Name Name of the source
16- 17 I2 h RAh Right ascension (J2000)
19- 20 I2 min RAm Right ascension (J2000)
22- 25 F4.1 s RAs Right ascension (J2000)
28 A1 --- DE- Declination sign (J2000)
29- 30 I2 deg DEd Declination (J2000)
32- 35 F4.1 arcmin DEm Declination (J2000)
38- 45 A8 "DD/MM/YY" Date Date of peak flux
49- 54 F6.1 mCrab Flux Peak flux in (2-30keV) range (1)
57- 61 F5.1 mCrab e_Flux Mean error on Flux (1)
65- 69 F5.2 h Ttot Total exposure time, when the source was
within TTM field of view
72- 74 I3 --- Ntot Number of sessions, when the source was
within TTM field of view
78- 82 F5.2 h Tid Time during which the source was identified
86- 88 I3 --- Nid Number of sessions during which the source
was identified
91- 95 F5.2 h T100 Number of hours when the flux was higher
than 100mCrab
99-101 I3 --- N100 Number of sessions when the flux was higher
than 100mCrab
105-110 F6.4 --- Tid/Ttot Ratio of the time Tid during which the source
was visible to the total time Ttot during
which it was within the TTM field of view
113-118 F6.4 --- T100/Ttot Ratio of the time T100 during which source the
flux was higher than 100mCrab to the total
exposure time Ttot
122-123 I2 --- N Number of sessions during which the source
was identified by TTM, with the
HEXE efficiency being nonzero (HEXE =
High-Energy X-Ray Experiment, 15-200keV]
127-164 A38 --- Notes Comments regarding the presumed nature
of the source and its type
--------------------------------------------------------------------------------
Note (1): the typical value of the mCrab is 2-3x10-11erg/cm2/s
(0.2-0.3fW/m2) in this energy range.
--------------------------------------------------------------------------------
History:
* 04-Sep-2000: prepared by Veta Avedisova [INASAN]
* 07-Apr-2011: fixed errors in the description of table1 above
(communication from Steve Drake, HEASARC): position in J2000
(was originally specified as 1950), and definition of the mCrab
removed. A table 2 most likely related to a paper by Taranova
(2000AstL...26..404T 2000AstL...26..404T = 2000PAZh...26..472T 2000PAZh...26..472T) has been removed.
(End) Veta Avedisova [INASAN] 04-Sep-2000